Model 9430 Regenerative 4-Quadrant AC Load

Regenerative AC Load that Simulates any Inductive, Capacitive, or Resistive Load

The 9430 is a current-regulated, 4-quadrant AC load with selectable phase inputs/outputs and a built-in waveform digitizing measurement system. In the sink mode, it sends power back to the facility mains rather than dissipated as heat. The 9430 has the capability of simulating almost any linear or non-linear load. Applications include testing of UPSs, AC sources, inverters, rectifiers, switches, circuit breakers and fuses

  • 8 Sizes – 4 to 96kW
  • Single, Split or Three-Phase programmable
  • 10 to 350VAC
  • 30 to 880Hz
  • DC operation to 10 to 400VDC
  • Reactive power capability 2.6 x Real Power
  • Sink power regenerated back to facility with >90% efficiency
  • Power factor range: -1 to +1
  • Crest factor range: 1.414 to 4.000
  • High-resolution waveform digitizer
  • 9” Touch-Panel user interface
  • High power density/minimum rack space

Advantages

  • Worlds 1st full-featured 4-quadrant AC Electronic Load
  • 100% Si-C based design with hi reactive current capabilities (HiVAR®)
  • 350VAC l-n up to 880Hz & 400VDC
  • Multiple Loading Modes including:
    • Constant Current (CC) / Power (CP) / VA (CS)
    • Constant Resistance (CR)
    • Constant Series RL (CRL)
    • User definable current waveforms
  • Simplifies automated test stand development
  • Built in measurement system:
    • Triggerable set &ammp; measurement
    • Software selectable 1, 2, or 3 Phase operation
    • Isolated digital inputs & outputs
    • Built-in SW watchdog & safety limits
  • Software tools to shorten test development time:
    • PC-based tools & NI certified drivers
    • NI certified LabVIEW & IVI-C/IVI-COM drivers

Benefits

  • Regenerative, returns greater than 90% of power to the facility, which provides significant electrical savings.
  • Field upgradeable to higher power
  • Fully emulate any power usage profile
  • Simulate non-ideal & transient phase currents
Model Power #phase Max
Reactive Power
AC Loading
Programmability
DC Loading
Programmability
Form Factor
9430-4-TP 4 kW 1 10.5 kVA 10 – 350Vrms L-N (30Hz–880Hz) 10-400VDC Chassis
9430-8-TP  8 kW 1 or 2 21 kVA 10 – 350Vrms L-N (30Hz–880Hz) 10-400VDC Chassis
9430-12-TP  12 kW 1,2 or 3 31.5 kVA 10 – 350Vrms L-N
(30Hz–880Hz)
10-400VDC Chassis
9430-24-TP  24 kW 1,2 or 3 63 kVA 10 – 350Vrms L-N
(30Hz–880Hz)
10-400VDC Cabinet
9430-36-TP 36 kW 1,2 or 3 94.5 kVA 10 – 350Vrms L-N
(30Hz–880Hz)
10-400VDC Cabinet
9430-48-TP 48 kW 1,2 or 3 126 kVA 10 – 350Vrms L-N
(30Hz–880Hz)
10-400VDC Cabinet
9430-72-TP 72 kW 1,2 or 3 189 kVA 10 – 350Vrms L-N
(30Hz–880Hz)
10-400VDC Double Cabinet
9430-96-TP 96 kW 1,2 or 3 252 KVA 10 – 350Vrms L-N
(30Hz–880Hz)
10-400VDC Double Cabinet